Hot water boilers are widely used in schools, hospitals, textiles, hotels, restaurants, bathrooms, etc. They are mainly distributed in densely populated areas, so they must be installed according to regulations. In order to avoid hidden dangers and safety accidents.
1. Location of hot water boiler:
The boiler must be placed in a reasonable position, not installed in the basement where the air is not smooth. The boiler must be flattened to avoid vibration during operation. The function of gas boiler ignition system is to ignite the mixture of air and fuel. Its main components are: ignition transformer, ignition electrode, electric fire high-voltage cable. A relatively safe ignition system is called electronic pulse igniter, which is widely used by Zhuoyi energy saving and other gas boiler manufacturers. It is convenient and time-saving. It can only be pressed by fingers, and it has high safety. There will be no safety accident due to accidental flameout. Once flameout occurs, the control system can timely close the solenoid valve and shut off the gas path. Damage to equipment.
2. Professional installation personnel:
In order to ensure the safe use of the boiler, the installation of the boiler must be carried out by professional installers with professional knowledge and installation experience. The gas-fired steam boiler adopts the way of combustion machine lower, two-way structure, full fuel combustion, stable operation and less space occupation of the boiler. At the same time, the smoke pipe is inserted with spoiler, which can slow down the speed of smoke exhaust, increase heat exchange, high thermal efficiency of the boiler and reduce the user’s use cost. The gas-fired hot water boiler has the remarkable characteristics of environmental protection, energy saving, safety and full-automatic operation, which is very useful In addition, gas-fired hot water boiler is more and more popular because of the operation economy and government policy encouragement. This is the first condition to ensure the safe operation of the boiler.
3. check whether there is air leakage:
When installing the gas boiler, open the gas valve to see if there is any leakage under the condition that there is no fire source nearby. If there is no air leakage, the installation is completed. If there is air leakage, it should be investigated and solved in time. Installation of flue gas: the flue gas of hot water boiler is the exhaust system for discharging flue gas, which will pollute the surrounding environment. The installation of flue gas must extend outwards. And there is a certain slope downward to prevent condensate backflow, resulting in corrosion of the furnace body. In addition, hot water boiler experts warned that in order to prevent unnecessary safety hazards, combustible materials should not be placed around the smoke pipe.